SOLID-2/SOLID-2E 
Safety Light Curtains 
  
 
产品资料下载 
 
SOLID-2/SOLID-2E安全光幕系统 
 
 
 	  
 
 
PDF阅读器:官方下载  
下载提示: 
1、产品详细资料为PDF文档; 
2、下载后若不能打开文档,请先安装PDF阅读器; 
3、下载时推荐使用下载工具或目标另存为。 
 
  
 
  
 
  
 
  
 
  
 
  
 
  
 
 
SOLID-2 / SOLID-2E - Safety Light Curtains	 
TüV NRTL US	TüV	CSA US	CE	IP 65 
Point of operation guarding: Light Curtain with finger resolution	Point of operation guarding: Light Curtain with hand resolution	Danger zone guarding: Light Curtain	Access guarding: Light Curtain 
A reliable and interference-proof safety sensor system is a prerequisite for high system availability and achievement of production targets. At the same time the increasing costs pressure of global competition also requires an economical safety system. 
 
Satisfying these central requirements was the maxim with the development of the SOLID-2 type 2 Safety Light Curtains with integrated cyclical testing. These devices are characterized by their robust housing design and high interference immunity. 
 
Various resolutions and functionalities enable cost-optimized solutions with the most varied applications. SOLID-2 is predestined for hand and arm protection and for detecting the presence of people. 
 
 
Special features 
Type 2 self-testing Safety Light Curtain in accordance with IEC/EN 61496 
 
SIL 2 Safety Light Curtain in accordance with IEC/EN 61508 
 
Slender and robust aluminum housing (30 mm x 34 mm) 
 
Fault-free operation of adjacent devices with selection of different transmission channels 
 
Easy function selection with external wiring 
 
Important technical data, overview 
Type in accordance with IEC/EN 61496	Type 2 
SIL in accordance with IEC 61508 and IEC/EN 62061	SIL 2 
Performance Level (PL) in accordance with EN ISO 13849-1	PL d 
Category in accordance with EN ISO 13849 and EN 954-1	2 
Resolution	20 mm	30 mm	40 mm	90 mm 
Range	0.5...15 m	0.2...10 m	0.8...20 m	0.8...20 m 
Protective field height (type-dependent)	150...1800 mm 
Profile cross-section	30 mm x 34 mm 
Safety-related switching outputs (OSSDs)	2 pnp transistor outputs 
Connection system	M12 plug 
Functions	SOLID-2	SOLID-2E 
Integrated cyclical testing		 
Automatic start/restart		 
Start/restart interlock (RES), selectable	 	 
Dynamic contactor monitoring (EDM), selectable	 	 
2 transmission channels, selectable		 
Function extension 
SOLID-2 
With Safety Interface	Relay output	RES	EDM	Muting	Cycle-control 
MSI-SR4				 	  
MSI-m *)					  
MSI-i *)				 	 
MSI-mi *)					 
SOLID-2E 
MSI-RM2		**)	**)	 	  
*) Can also be connected to SOLID-2E **) Already included in the device 
 |